The East Bank and West Bank Waterworks Districts were created in November 1949 and were operated as separate districts under separate boards of commissioners. These two districts were combined into a Department of Waterworks under St. Charles Parish by the parish council on Nov. 6, 1989.
How Water Is Made
Mississippi River
St. Charles Parish has no known aquifers with an adequate supply of potable water. Therefore, the source of drinking water is the Mississippi River.
Process and Function
The water treatment systems on the East and West Banks are similar and consist of:
PROCESS | TREATMENT FUNCTION |
---|---|
Clarification | Coagulation / flocculation using a cationic polymer in an upflow clarifier. |
Filtration | Removal of small particles with a sand / gravel media. |
Disinfection | Using chlorine anhydrous ammonia to kill harmful bacteria. Disinfection destroys waterborne infectious diseases, including typhoid fever, cholera, dysentery, infectious hepatitis, etc. |
Fluoridation | Hydrofluosilicic acid added to obtain 0.85 + 0.15 parts per million of fluoride for the prevention of dental cavities. |
Corrosion Inhibitor | KS 9200 used to prevent rusting and metal leaching. |
Powdered Activated Carbon | Removes organics, improves taste/odor. Also removes disinfection byproducts. |
Plant Storage | Ground storage tanks maintain a reserve supply. |
KS 9200 | Helps stabilize Chloramines. Also helps prevent disinfection byproducts. |
Water Treatment Chemicals | Underground piping to deliver water to customers, fire hydrants for fire protection, elevated tanks for storage and stabilizing pressure. |
Chemicals Involved in the Treatment Process:
-
Cationic Polymer
A food grade material (polydimethyl diallyl ammonium chloride) which possesses a positive ion charge. Dispensed in water, this material will attract negatively charged materials, such as clay (dirt) in the raw river water to coagulate or bring together impurities in a dense mass. The coagulated mass will flocculate and sink to the bottom of the clarifier. Clear water is decanted off the upper zone and transferred to a sand filter where all visible particles are removed.
-
Chlorine
A powerful oxidant that disinfects water by killing bacteria. In order to maintain disinfection, a chlorine residual must be continued in the distribution system.
-
Ammonia
When combined with chlorine, ammonia forms chloramine. Chloramine is used instead of chlorine in the distribution system to maintain disinfection and to minimize objectionable chemical side reactions.
-
Hydrofluosilicic Acid
Added to drinking water to prevent dental cavities in young children.
-
KS 9200
Added as a corrosion inhibitor. Helps stabilize chloramines, Also helps prevent disinfection byproducts.
-
Powdered Activated Carbon
Added continuously for taste and odor control.
Specifications and Diagrams
To view the distribution system specifications with diagrams, click here. To view the distribution system specifications without diagrams, click here.
To view the distribution system specifications broken down into sections, view the table of contents and then select the section you wish to view.
Water Standards
Water must be pleasing to the senses, clear, odorless and taste-free, free of harmful bacteria and have no harmful contaminants. There are more than 80 Environmental Protection Agency (EPA) drinking water regulations, including inorganic chemicals, organic chemicals, disinfection by-products, turbidity, microbiological contaminants and radio-nuclides. Water quality testing and analysis are performed to monitor all plant treatment functions and water in the distribution system. All laboratory analyses required to meet the monitoring requirements of the U.S. EPA drinking water quality regulations are performed by the Louisiana Department of Health and Hospitals. St. Charles Parish drinking water meets and exceeds all quality requirements.
Water Quality Testing and Analysis
Treatment plant operators perform tests and analyses to assure that clarification, filtration and disinfection treatment processes are performing to yield the optimum quality of water. All plant data is placed in computers for processing and storage. Information can be easily retrieved and is calculated and arranged in a logical fashion so that the treatment processes can be reviewed for troubleshooting. Some plant data are automatically recorded, and some pumps and motors can be manually turned on or off by using computer controls. Maintenance is being guided by computerized information.
Water quality safety is assured by the comprehensive control of all water treatment processes. For example, chlorine addition levels are checked for continuity throughout the treatment system and are verified by three independent measurement methods. Clarification polymer levels are verified by predetermined calculations to assure minimum addition levels. Powdered activated carbon is fed at 0.5 parts per million continuously as a safeguard against contamination by most levels of organic materials. This addition level can be adjusted promptly as needed to remove higher levels of organic contaminants.
Emergency procedures are in place for any foreseeable problem situation. Most procedures emphasize prevention and utilize reduced water pressure to conserve drinking water reserves. Waterworks has emergency procedures for hurricanes, hard freezes, oil and chemical spills, chlorine and ammonia leaks.
Analyses and Tests Performed by Waterworks
- Raw water conditions: Monitor polymer addition levels, flow rate and temperature.
- Clarifiers: Monitor polymer addition levels, solids and speed.
- Entire treatment process: Test for turbidity.
- Filtration and storage systems: Analyze for chlorine and ammonia disinfection levels. Analyze for fluoride.
- Monitor chlorine, ammonia, fluoride, corrosion inhibitor and activated carbon addition levels.
Perform Water Analyses On
RAW CONDUCTIVITY | TO DISTRIBUTION CONDUCTIVITY | IN DISTRIBUTION CONDUCTIVITY |
---|---|---|
pH | pH | |
Total Hardness | Total Hardness | |
Alkalinity | Alkalinity | |
Fluoride | Fluoride | Fluoride |
Free Chlorine | Free Chlorine | Free Chlorine |
Total Chlorine | Total Chlorine | Total Chlorine |
Coliform Bacteria (Colilert) | ||
Heterotrophic Plate Count | ||
Temperature | Temperature | Temperature |
Water Treatment Capacity
-
East Bank
10 million gallons per day. Average production 4.4824 million gallons per day.
-
West Bank
9 million gallons per day. Average production 4.6439 million gallons per day. Maximum daily production 6.3814 million gallons per day. This system has an ample supply of water available for additional commercial, industrial or business ventures and for residential expansion.
The Waterworks Department has emergency procedures in place for any foreseeable emergency. Most procedures emphasize prevention and utilize reduced water pressure to conserve drinking water reserves. Waterworks has emergency procedures for hurricanes, hard freezes, oil and chemical spills and chlorine or ammonia leaks.
Freeze Precautions
- All exposed pipes should be insulated and shielded from the wind. Exposed piping underneath a house or in the walls should be protected by draining. Houses on slabs do not need protection if the piping is in the slab. The supply line must be protected by wrapping with insulation, newspaper or old clothing. Plyboard, felt roofing, plastic or cardboard can be used for shielding.
- To drain piping, close the valve on the water supply line and open all faucets. Draining will only work if pipes slope evenly.
- When the water supply is to be shut off, the hot water heater must be turned off. The valve on gas heaters should be set to the "pilot" position. Electric heaters should be turned off at the switch box.
- In order to keep the meter from freezing, the meter box cover must be kept in place with the lid closed.
- If customers feel the need to leave water running during freezing weather as a means of preventing frozen or burst piping, expect a bill increase as a result of this action. The Department of Waterworks recommends that water pipes should be insulated and shielded from the wind as the primary means of protection. Flushing should be used as a last resort.
Hurricane and Tornado Preparations
- Reserve a water supply for drinking by placing water in sealed containers.
- Clean the bathtub and fill it with water.
- Keep a bucket in the bathroom to use to fill the toilet with flushing water and for "wash-off" baths.
- Electric hot water heaters should be turned off.
- Gas hot water heaters should be set on pilot.
- If the customer has to leave home to take shelter elsewhere, the outside water valve at the house should be turned off.
Chemical Spills
- Precautions are taken by Waterworks to prevent contamination of clarifiers and filters. This often requires a shutdown of water intakes from the river. When the water intake is discontinued, the reserve storage is used to supply water to customers. As the reserve supply decreases, water pressure is reduced to decrease consumption. When conserved in this manner, water reserves can be made to last for much longer periods of time.
- If the contaminant floats as with oil, booms are installed at the river intake pipes. Skimmers are used on the clarifier surfaces to remove any oil accumulations. The clarifiers are equipped with covers that extend below the water surface to keep oil out of the filters.
It is the policy of the Waterworks Department not to relocate fire hydrants. A customer may move the hydrant, at their expense, provided they retain a qualified contractor, install the hydrant according to Waterworks' specifications and submit a detailed plan for approval.
For fire hydrant specifications refer to:
Waterworks is obligated by parish ordinance 91-7-7, Water Revenue Bond, Series 1991, Article IX, Section 901, to fix, establish and maintain rates and fees and to revise them whenever necessary to provide sufficient revenues to:
- Pay the necessary expenses of administering, operating and maintaining the utilities system.
- Pay the principal and interest on maturing bonds.
- Maintain all other funds required by the ordinance.
- Pay all other obligations and indebtedness of the utilities system.
- Maintain each year, after paying all necessary expenses of administering, operating and maintaining the utilities system, funds at least equal to 120 percent of the largest amount of principal and interest due on revenue bonds.
Waterworks is further obligated by Ordinance 91-7-7, Water Revenue Bond, Series 1991, Article IX, Section 902:
- To fix, maintain and collect rates and fees irrespective of the user.
- No free services or facilities be furnished to any person, association of persons or corporation, public or private.
- All services shall be metered.
- No discrimination shall be made as to rates and charges for the services and facilities of the utilities system as between users of the same type or class.
- There be no rental or fee charged for fire hydrants connected to the utilities system and available for fire fighting purposes.
- There be no charges for water used for firefighting or street cleaning.
- All charges for any individual, partnership or corporation be billed and collected as a unit.
- Failure of any individual, partnership or corporation to pay said combined charges within 15 days of the date on which it is billed shall cause such charge to become delinquent and shall be charged a 10 percent penalty on the bill charges.
- If the bill and the penalty charges remain unpaid from the date on which it became delinquent, Waterworks will shut off water service to the affected premises until all bill charges, penalty fees and reconnection fees are paid.
- All rates, fees and charges in effect on the date of this ordinance are to remain in effect and shall not be reduced at any time.
Effective January 1, 2024, Parish Code of Ordinances, Chapter 23, Article I, Section 23-3 (e)
Residential, Commercial, Industrial, Lafourche, St. John, Special, Fire Lines
- $4.00 one month minimum
- $4.43 per 1,000 gallons - 0 to 6,000 gallons
- $6.42 per 1,000 gallons - 6,001 - 10,000 gallons
- $8.14 per 1,000 gallons - Over 10,000 gallons
Second Residential - User Code 8
- $2.00 one month minimum
- $4.43 per 1,000 gallons - 0 to 6,000 gallons
- $6.42 per 1,000 gallons - 6,001 - 10,000 gallons
- $8.14 per 1,000 gallons - Over 10,000 gallons
Fire Hydrant Meter Services - User Code 4
- $10.00 one month minimum
- $4.43 per 1,000 gallons - 0 to 6,000 gallons
- $6.42 per 1,000 gallons - 6,001 - 10,000 gallons
- $8.14 per 1,000 gallons - Over 10,000 gallons
Other Charges on Water Bill
Wastewater Rates Effective January 1, 2024:
- $4.16 one month minimum
- $9.50 per 1,000 gallons (100 percent usage)
- $9.03 per 1,000 gallons ( customer charged at 95 percent usage for commercial)
- $8.55 per 1,000 gallons (customer charged at 90 percent usage for second residential meter)
- $7.60 per 1,000 gallons (customer charged at 80 percent usage)
Solid Waste Rates:
- $21.12 per month (change effective July 25, 2024)
Louisiana Sales Tax:
- 2.0 percent on commercial and industrial sales
For more Information click here.
Sewer Installation Charges (St. Charles Parish Code, Chapter 22, Section 22-80):
- As levied by the Wastewater Department
Delinquent Fee (St. Charles Parish Waterworks District 2 Ordinance 8-8-78, Effective Oct. 1, 1978):
- 10 percent on water, wastewater, and solid waste only
AVERAGE RESIDENTIAL WATER BILL BASED ON 5,400 GALLONS WATER USAGE PER MONTH | |
---|---|
Water | $24.47 |
Wastewater | $39.11 |
Garbage | $19.12 |
Total | $82.70 |
SERVICE FEES EFFECTIVE FEBRUARY 1, 2015 METER SIZE |
NON-REFUNDABLE SERVICE CHARGE |
REFUNDABLE METER DEPOSIT *** |
---|---|---|
5/8 inch x 3/4 inch residential meter * |
$825 | $130 |
5/8 inch x 3/4 inch (second residential for irrigation) * |
$825 | $50 |
1 inch residential meter * |
$1,100 | $180 |
1 inch (second residential for irrigation) * |
$1,100 | $75 |
2 inch * ** | $3,500 | $375 |
3 inch *** ** | $30 | $1,200 |
4 inch *** ** | $30 | $1,800 |
6 inch *** ** | $30 | $2,700 |
8 inch *** ** | $30 |
$3,200 |
Fire hydrant meter (nonpotable water) | $30 | $150 |
* Meter furnished by district
** Customer must install and maintain a reduced pressure backflow preventer, and a strainer is required in front of all 2-inch and larger meters.
*** Customer must have meter installed. District must be notified prior to tapping the main.
**** A deposit must be made before a meter can be opened for service.
Industrial Customers must install a backflow preventer regardless of meter size.
Meter Deposit Transfer
When a customer wants to close one account and open another, the existing meter deposit on the old account will be transferred to the new account, regardless of the amount as of June 19, 1991. The transfer must be made within five working days, or another deposit must be made on the new account.
Connect Fee
$30 to read and/or open existing services.
Reconnect Fee
$30 to open services locked off for delinquent bills or NSF checks.
Damage Fee
$30 plus $30 reconnect fee and actual labor costs and material cost to repair any damages incurred to reconnect if a meter was picked up due to unauthorized opening of service by the customer.
Actual Labor Costs for Repairs
|
|
Actual Cost for Damaged Materials
|
|
Shut Off Valve Fee During Office Hours
$30 per trip to turn the valve off or on when requested by the customer.
Shut Off Valve Fee After Office Hours and Holidays
$100 per trip after office hours, on weekends and holidays. Note that customers will be requested to have a shut off valve installed on their side of the meter. Waterworks will turn on/off during office hours without charge if the customer is installing a shut off valve.
NSF Check Fee
$30 Per check returned "NSF" or "account closed" as of Nov. 3, 2011.
Meter Information
- The meter register is in gallons, not cubic feet.
- All numbers are read except the last two.
- Meter size is 5/8 inch x 3/4 inch.
- 5/8 inch is the inside diameter, which affects flow.
- 3/4 inch is the outside diameter for fittings.
- The arrow indicates direction of flow.
Meter Coupling
A leak before the meter does not affect consumption. Waterworks is responsible for leakage in the meter/coupling junction on the customer's side. A leak after the meter is registered by the meter. The customer is responsible for the leak at the junction with customer line/meter couplings.
Curb Stop
The curb stop is Waterworks' valve inside the meter box behind the meter. Waterworks uses the curb stop to turn the meter on and off.
Customer's Water Valve
This is the customer's valve that the customers use to turn their water on and off.
- Always close lids on meters and tops on meter boxes.
- Customers should report all broken or missing meter boxes and/or lids.
- Meters are removed from accounts that have been vacant for six months or more.
Water Meters
The following water meters are used in St. Charles Parish.
SIZE | MAKE | FLOW RATE-GPM LOW |
FLOW RATE-GPM HIGH |
---|---|---|---|
5/8 inch x 3/4 inch |
Master Meter BLMJ w/Dialog 3G AMR |
1/4 | 20 |
1 inch |
Master Meter BLMJ w/Dialog 3G AMR |
3/4 | 50 |
2 inch |
Master Meter Octave Ultrasonic Meter |
1/4 |
250 |
3 inch |
Master Meter Octave Ultrasonic Meter |
1/2 |
500 |
4 inch |
Master Meter Octave Ultrasonic Meter |
3/4 |
1000 |
6 inch |
Master Meter Octave Ultrasonic Meter |
2 |
1600 |
8 inch |
Master Meter Octave Ultrasonic Meter |
4 | 2800 |
- All meters shall be read in U.S. gallons, and the main cases shall be bronze.
- The meter should be sized based on flow rates rather than pipe size.
- Click here to find meter specifications.